HC241P
105kW / 241.152kWh
High-capacity all-in-one PV+battery cabinet with integrated inverter and MPPT. Designed for C&I peak shaving, self-consumption, and backup power.
Rated Power
105kW
Capacity
241.152kWh
Battery Type
LiFePO4
Cooling
Air Cooling

All-in-One Design.
Zero Compromise.
Safe & Reliable
LiFePO4 cells with multi-layer protection: thermal warning algorithms, fire suppression, and explosive venting.
CCS Module Design
Standardized cell-to-system modular architecture for rapid deployment and flexible capacity configuration.
Short Response Time
Millisecond-level response for peak shaving, demand response, and grid frequency support applications.
PV Integration
Built-in PV input with MPPT optimization — a true all-in-one PV + battery + inverter system in a single cabinet.
Flexible Grid Switching
Seamless on-grid / off-grid transfer switching for uninterrupted power supply during grid outages.
User-Friendly
Intuitive monitoring interface, OTA firmware updates, and remote diagnostics via cloud-based EMS platform.
Technical Specifications
| Rated Power | 105kW |
| Maximum Current | 167A |
| Rated Voltage | 400V |
| Wiring Method | 3P4L+PE |
| Frequency | 50Hz / 60Hz |
| Power Factor | 1 (Leading) ~ 1 (Lagging) |
| THDi | <2% (Rated Power) |
| Rated Power | 105kW |
| Rated Voltage | 400V |
| Maximum Current | 167A |
| Wiring Method | 3P4L+PE |
| Frequency | 50Hz / 60Hz |
| THDu | <3% (Linear Load) |
| Battery Type | LiFePO4 |
| Battery Cell | 3.2V / 314Ah |
| Battery Pack Configuration | 1P16S |
| Battery Pack Quantity | 15 Packs / Cluster |
| Rated Current | 157A |
| Voltage Range | 648 – 864V |
| Rated Capacity | 241.152kWh |
| Max. Usable PV Input Power | 120kW |
| Max. Input Current | 50A × 4 |
| Max. Short Circuit Current | 60A × 4 |
| Max. Input Voltage | 900V |
| MPPT Voltage Range | 200 – 850V |
| Start-up Voltage | 250V |
| MPPT Number | 4 |
| Weight | 2.8T |
| Dimensions (W×D×H) | 1800×1100×2250mm |
| Maximum Efficiency | ≥85% |
| Air Conditioning Power | 3kW (Cooling), 2.5kW (Heating) |
| Temperature | -20°C ~ 50°C (De-Rating Over 45°C) |
| Humidity | 5% ~ 95%RH (Non-Condensation) |
| Protection Level | IP54 |
| Anti-corrosion Rating | C4 |
| Cooling Method | Air Cooling |
| Noise | ≤75dB |
| Altitude | 2000m (>2000m Derating) |
| Display | LCD |
| Fire Protection | FK-5-1-12 |
| Communication | Ethernet |
| Certification | CE, UN38.3 |
| Charge/Discharge Rate | 0.5CP |
| Depth of Discharge | 90% |
| Cycle Life | ≥6000 Cycles (80% SOH @ Standard) |
Built for C&I
Energy Management.
Industrial Peak Shaving
Reduce peak demand charges by 30–50% through intelligent charge/discharge scheduling aligned with tariff periods.
PV Self-Consumption
Maximize on-site solar utilization with integrated MPPT and battery buffering — minimize grid export and maximize ROI.
Backup Power
Seamless off-grid switching ensures uninterrupted power for critical loads during grid outages.
Interested in the HC241P?
Share your site requirements and our engineering team will provide a detailed system configuration and commercial proposal.